Cork Quality Council 
Quality Control Procedures


Cork Quality Council 
Forestville CA
707-887-0141

info@corkqc.com


Return to Main Menu


A Renewable Resource


The Cork Forest
   


The Whistler Tree (World's Largest Cork Tree)
   


How Natural Cork  is Harvested 
 


Industry Statistics
   


Consumer Views on Natural Cork
 


CQC Quality Control Procedures
 


Suggested Winery QC Procedures
   


Visual Grading Standards

   


Progress in avoiding "Cork Taint"


CQC Members

Amorim Cork America

Corks Supply USA

Juvenal Direct

Ganau America

Lafitte Cork 
and Capsule

M.A. Silva
Corks USA

Portocork America

Scott Laboratories

Top of Page

Comments or suggestions may be mailed to info@corkqc.com
Members of the Cork Quality Council adhere to specific guidelines governing quality control procedures. Rules of membership require a domestic production facility available for inspection. Compliance with quality control guidelines are strictly audited and provide a minimum standard for the following procedures: 

Quality Control Standards for:

    1. Inbound Cork Shipments
    2. Outbound Cork Shipments
    3. Agglomerated Cork Construction

Incoming Cork Procedures

I. Sampling Plan

Individual lots of corks should be sampled using US Government Military Standard 105-D plan. From the sample taken, smaller sub-samples are randomly selected to undertake the following quality tests.

II. Acceptance/Rejection

Guidelines for acceptance and rejection to follow US Government Military Standards 105-D Inspection Plan (reduced inspection), at the various acceptance levels as indicated per test below.

III. Test Procedures

    A. Sensory Test:
    The number of corks to be tested will be in accordance with Mil Std 105-D. Six corks from each bale taken as per III.A1 above will be immersed in a 500ml container of neutral dry white wine for 24 hours, then checked organoleptically for changes in sensory character when compared to a control wine. If TCA taint is suspected, an immersion test will be made from six corks from every bale. Any bale with TCA taint will be rejected. 

    B. Visual Quality:
    Corks sampled, at minimum, will be in accordance with Mil Std 105-D (reduced). Individual corks are classified into predetermined categories depending on the physical qualities agreed on with the producer. 

    C. Moisture:
    Cork moisture will be tested on a sample size of 25% of the Mil Std 105-D (reduced) per lot. A cork moisture instrument will be used. Cork shipments should be received with a moisture level below 8% average, with a tolerance per AQL 4.0.

    If moisture level average is above 8% but below 10.5%, the following procedure may be followed: 

    • Corks are to be placed in a drying area which is physically separate from the storage area for accepted corks. 
    • When corks are resampled for reduced moisture levels, the cork moisture will be tested on a sample size of 25% of the Mil Std 105-D (reduced) per lot. A cork moisture instrument will be used. Moisture level must be below 7.5% average, with a tolerance per AQL 4.0. 
    • All sensory testing must be done again following procedure outlined in III.A before corks can be accepted into ongoing inventory of corks suitable for sale. 
    D. DIMENSIONS:
    Cork dimensions will be checked on a sample size of 25% of the mil Std 105-D (reduced) per lot using an electronic or dial caliper accurate to +/- 0.01mm. Tolerance range per ISO3863 and acceptance at Military Standards 105-D. 
    Diameter: as specified (+/- 0.50 mm) AQL = 1.5 Length: as specified (+/- 1.00mm) AQL = 4.0

    E. RESIDUAL OXIDANTS:
    One cork from each bale taken as per paragraph III.A1 above will be tested using a qualitative analysis involving the reaction of potassium iodide with residual oxidants in the presence of a starch indicator. A change in the test solution from clear to blue/violet color is a positive result.

    Acceptance: 

    • Traditional washed: per CTCOR 
    • Peroxide washed: ZERO 
    • Natural (Metabisulfite): ZERO 
IV. Lot Definition

A lot is defined as a particular wood quality, size, and wash from an individual supplier in a single shipment.

V. Records 

Permanent records of the quality control tests for each lot will be kept by the Supplier for a period of at least five years. 
 
 

Top of Page







Outbound Cork Procedures

I. Test Procedures
    A. BATCH QUALITY 
    The batch quality should match any samples presented to clients on which the order was based. Cork samples sent to a client should contain a minimum of 24 corks.

    B. CORK MOISTURE
    Randomly sampled corks from the prepared batch are analyzed using the sample procedure outlined in Incoming Cork QC. Prepared batches should have an average moisture range between 5% - 8%.

II. Sulfur Dioxide

An injection of at least 2 grams of sulfur dioxide should be added to each bag of corks for the control of micro organisms.

III. Records 

Permanent records of the quality control tests for each lot will be kept by the Supplier for a period of at least five years. 

IV. General

Every reasonable effort will be made to ensure the pristine character of the corks is preserved while in processing at members’ facilities.
 
 

Top of Page







CQC Standards for 
Agglomerated Corks with Disk

(1) Recovery from Compression:
    Compress cork to a diameter of 1/3 the original size allowing deformation for 24 hours. Diameter is measured as a percent of the original size after 15 minutes.

    Acceptable values: Min 80% Target 90-95%

(2) Specific Weight
    Measure agglomerated cork - without disks - at max 6% humidity level(1) Measurements recorded as a ratio in terms of Kilograms per cubic meter.

    Acceptable Values: Min 255kg Max 320kg

(3) Migration
    Treated stoppers are marked and placed on their bases in a colored ethanolic solution containing 10% alcohol by volume which will reach a height of 3mm on the cork. After 24 hours remove the stoppers and measure the maximum height reached by the solution. Measurement should be rounded off to the nearest .5mm.

    Acceptable Values: 3mm - and not to exceed disk

(4) Torsion
    Torsion will be measured in accordance to NP2803 A Method - whereby the cork is submitted to torsion at a 100o/min rate - twisting until the cork cracks. Measurement will be in terms of shear strength as measured by the formula 16T/pd3 where d is the diameter of the cork and T is the momentum calculated as T=FxBxsin(a/2) where a is the torsion angle.

    Acceptable Values Min 7 daN/cm2 

(5) Residuals
    Treated or Untreated stoppers are marked and placed in a an ethanolic solution containing 10% alcohol by volume adjusted to 3.5ph. Vigorously agitate for 20 minutes. Filter solution using a .45 micron membrane. After drying weigh any residuals in a ration of mg/cork.

    Acceptable Values < 2.0 mg per cork

(6) Binders
    Binding agents will be prepared in compliance with USFDA regulations as seen in Title 21 CFR 175 Subpart B [175.105].
(7) Composition
    Agglomerate corks must contain a minimum 80% natural cork as measured by weight. Methodology for compliance is being researched.



 
 